← Engineering Tools
🛡️
Pipe Wall Thickness Calculator
Per ASME B31.3 Process Piping Code
t_min = P × D / (2 × (S × E + P × Y))
P=1000 kPa, D=88.9 mm, S=138 MPa, E=1.0, Y=0.4
Common Pipe Schedule Lookup
| NPS | OD (mm) | Schedule | Wall (mm) | ID (mm) |
|---|---|---|---|---|
| 1/2" | 21.3 | 40S | 2.77 | 15.8 |
| 1/2" | 21.3 | 80S | 3.73 | 13.8 |
| 1/2" | 21.3 | 160 | 5.54 | 10.2 |
| 3/4" | 26.7 | 40S | 2.87 | 21 |
| 3/4" | 26.7 | 80S | 3.91 | 18.9 |
| 3/4" | 26.7 | 160 | 6.35 | 14 |
| 1" | 33.4 | 40S | 3.38 | 26.6 |
| 1" | 33.4 | 80S | 4.55 | 24.3 |
| 1" | 33.4 | 160 | 8.03 | 17.3 |
| 1-1/2" | 48.3 | 40S | 3.68 | 40.9 |
| 1-1/2" | 48.3 | 80S | 5.08 | 38.1 |
| 1-1/2" | 48.3 | 160 | 10.03 | 28.2 |
| 2" | 60.3 | 40S | 3.91 | 52.5 |
| 2" | 60.3 | 80S | 5.54 | 49.2 |
| 2" | 60.3 | 160 | 11.03 | 38.2 |
| 3" | 88.9 | 40S | 5.49 | 77.9 |
| 3" | 88.9 | 80S | 7.62 | 73.7 |
| 3" | 88.9 | 160 | 11.68 | 65.5 |
| 4" | 114.3 | 40S | 6.02 | 102.3 |
| 4" | 114.3 | 80S | 8.56 | 97.2 |
| 4" | 114.3 | 160 | 13.51 | 87.3 |
| 6" | 168.3 | 40S | 7.11 | 154.1 |
| 6" | 168.3 | 80S | 10.97 | 146.4 |
| 6" | 168.3 | 160 | 18.77 | 130.8 |
| 8" | 219.1 | 40 | 8.18 | 202.7 |
| 8" | 219.1 | 80 | 12.7 | 193.7 |
| 8" | 219.1 | 120 | 16.66 | 185.8 |
| 10" | 273.1 | 40 | 9.27 | 254.6 |
| 10" | 273.1 | 80 | 12.7 | 247.7 |
| 10" | 273.1 | 120 | 19.05 | 235 |
| 12" | 323.9 | 40 | 10.31 | 303.3 |
| 12" | 323.9 | 80 | 14.27 | 295.4 |
| 12" | 323.9 | 120 | 22.23 | 279.4 |